1. Digital thermostat water bath first flashes after power display dfs, after the display date, to detect whether there are missing digital tube strokes. 2. Press the SET button for the first time, the indicator light SL is on, enter the temperature setting state, press the up key, adjust up 0.5°C, press down the key, down 0.1°C. 3. Press the set button for the second time, the first digit displays d, and enter the set advanced control temperature value, which can be adjusted at 0-5°C. (For example: if the temperature is set to 50 °C, if the temperature is 0.5 °C, in order to avoid the flushing temperature d will be adjusted to 0.5, so that heating to 49.5 °C to disconnect the heating; and if the setting temperature is 90 °C, if the temperature exceeds 1 degree, Adjust d to 1 and finally heat to 89 °C. 4. Press the set key for the third time, the first digit will display C or -, and enter the temperature deviation adjustment, which can be adjusted at -9.8 to 9.9°C. (For example: When the display temperature is 0.5 °C lower than the actual temperature, adjust C to 0.5 °C, so the actual and display the same; when the display temperature is 0.5 °C greater than the actual temperature, the C is adjusted to -0.5 °C, so the actual and display consistent) . 5. Press the set key for the fourth time to return to the measurement state. If the set value is the automatic control, after the set value is set to the end, if you do not press the set key to return to the measurement state, the temperature control table will be automatically after 5 seconds. Jump back and work. 6. Press and hold the setting key for 5-8 seconds to automatically reset the set temperature value to 00.0°C. Before setting the temperature for the first time, if the set temperature is not normal, it should be reset before use. 7. If it is a high-precision temperature control, 3-5 and 3-6 do not need to operate; In addition, press the setting button again, the upper row shows -d, indicating that the setting of the minimum heating power coefficient, the boot automatically is 3, can be in 1 -8 adjustments. Can be set to 7-8 in semi-closed state; fully closed state is 1-2 8. At the end of the work, press the set button for about 5 to 8 seconds. The temperature control system will automatically reset. When the set temperature is restored to 00.0°C, turn off the heating power. (If the work is completed, do not press the set button to reset the position and turn off the power directly. Then the temperature control system will record the original settings after the next restart). 9. If the water bath time is not used, drain the water from the studio tank and wipe it with a soft cloth and let it dry.
GJCNC-BP series CNC busbar punching & shearing machine is the computer-controlled equipment of high efficiency and high precision, specially used for busbar processing; Dies of punching, shearing are placed together in the storeroom of dies; It is capable of executing punching(round, oblong and other holes), shearing, slotting, round cornering and other processes; Automatic clamp switching can be achieved without manual intervention for longer busbars. Finished work pieces will be sent out through the conveyor. Such machine series can be used in combination with the CNC Busbar Bending Machine to form an assembly line of busbar processing.
Turret Punching Machine,Busbar Punching Machine,Cnc Turret Punching Machine,Servo Punch Machine JINAN EURO-ASIA MACHINERY CO., LTD , https://www.euroasiamachine.com