Recently, the LED industry has been in short supply from upstream chips to downstream packaging plants. The industry also generally expects May revenue to be better. Some insiders expect that with the launch of the LED lighting market, the annual LED market demand will increase by more than 30. In the first half of the year, the LED chip industry will have a new capacity of less than 10, and the supply and demand situation of the LED chip industry will be more balanced in the second half of the year. Tightening.
Among the A-share listed companies in China, the 144 MOCVD equipments of the third chip factory under the LED chip leader Sanan Optoelectronics were all filled except for the R&D machines. The company plans to add 200 MOCVD machines in Xiamen. It is expected that the company's MOCVD equipment is expected to reach 400 units in 2016. The company has formed a sapphire substrate-LED chip-LED factory lighting full LED industry chain, and will rank among the top five in the world in the future. pattern.

Metal Body Square Water Cooling Tower

This series of products run stable, low noise, energy-saving, in office buildings, shopping malls, hotels, residential areas and other central air-conditioning supporting the use of better results.

The company's standard cooling tower according to the international design conditions design, can also provide customers with non-standard operating conditions or specific sizes under the special, special design.

The circulating water pump suction port shall be located below the water level of the cooling tower catchment basin, and the cooling tower outlet pipe shall not be allowed to be higher than the maximum water level of the catchment basin.
Pipe mounts should be pipe racks and cooling towers should not be allowed to directly bear the weight of the pipes.

The rehydration pipe of the cooling tower should be provided with a support stand to avoid vibration of the pipe when the float valve is rehydrated.

Rehydration pressure should be below 5m water pressure, national standard
The flannage pressure is 1.0Mpa.

When two or more units are assembled, our company will provide a connecting balance tube to balance the chassis water level. The tower top inlet should be set with a conditioning valve in order to enter each
.The water level of the tower is uniform.


The noise is measured at dm1.13VL-W at the equivalent diameter of the cooling tower (Dm1.13VL*W), 1.5 meters above the ground height, wherein L and W are the shape rulers of the tower
inch long and wide).

The use of cellular continuous blister series of diversion,heat dissipation, water collection three-in-one native filler, the whole suspension, gravity cloth water, low drop of water, with cold effect
High, low energy consumption, less drift water, less noise and so on, floating water rate is less than 0.001%.

When connecting different types of towers, the bottom basin water level height of different types of towers must be taken into account, and the base height must be adjusted to maintain the water level balance of the towers.

Metal Body Square Water Cooling Tower,Tower Water Cooler,Water Cooled Cooling Tower,Tower Cooling System