Safety 3Ply Face Mask, Protective Face Mask, Non Woven Surgical Mask, Anti virus Surgical Mask GUANGZHOU HTD INTERNATIONAL , https://www.htdmask.com
1.Brushless synchronous alternator with Stamford technology.
2.Output range:6.5kw - 1150kw single-phase and three-phase
3.High-performance Convenient installation and maintenance
4.Three phase 4 wire, optional 50Hz/60Hz, 1500/1800RPM
5.4-pole, brushless alternator with AVR, H class insulation, IP21
6. Be suitable for various brands engine, international standard SAE port, double bearing as optional
Specifications:
Â
MODEL
3-PHASE 50Hz /1500RPM 380V-440V
3-PHASE 60Hz /1800RPM 440V-480V
DIMENSION
WEIGHT
(KVA)
(KW)
(KVA)
(KW)
CM
KG
JETÂ 164A
8.1
6.5
10.2
8.2
64×54×72
95
JETÂ 164B
11
8.8
13.8
11
64×54×72
102
JETÂ 164C
13.5
10.8
16.9
13.5
64×54×72
110
JETÂ 164D
16
12.8
20
16
64×54×72
116
JETÂ 184E
22.5
18
28.8
23
84×59×75
133
JETÂ 184F
27.5
22
34.4
27.5
84×59×75
156
JETÂ 184G
31.3
25
37.5
30
84×59×75
172
JETÂ 184H
37.5
30
46.9
37.5
84×59×75
226
JETÂ 184J
40
32
50
40
84×59×75
236
JET 224C
42.5
34
52.5
42
96×66×102
275
JET 224D
50
40
62.5
50
96×66×102
295
JET 224E
60
48
70
56
96×66×102
315
JET 224F
72.5
58
87.5
70
96×66×102
345
JET 224G
85
68
97.5
78
96×66×102
385
JETÂ 274C
100
80
118
94
126×76×102
415
JETÂ 274D
114
91
138
110
126×76×102
435
JETÂ 274E
140
112
168
134
126×76×102
485
JETÂ 274F
160
128
190
152
126×76×102
530
JETÂ 274G
175
140
213
170
126×76×102
580
JETÂ 274H
200
160
245
196
126×76×102
630
JETÂ 274J
230
184
281
224.8
130×76×102
750
JETÂ 274K
250
200
299
239.2
130×76×102
760
JETÂ 444C
250
200
294
235
151×79×107
880
JETÂ 444D
295
236
350
280
151×79×107
950
JETÂ 444E
325
260
394
315
151×79×107
1065
JETÂ 444FS
380
304
456
365
151×79×107
1145
JETÂ 444F
400
320
480
384
151×79×107
1185
JETÂ 544C
450
360
550
440
165×95×116
1350
JETÂ 544D
500
400
594
475
165×95×116
1450
JETÂ 544E
600
480
713
570
165×95×116
1700
JETÂ 544FS
625
500
725
580
165×95×116
1753
JETÂ 544F
670
536
775
620
165×95×116
1820
JETÂ 634B
750
600
855
684
180×100×145
2020
JETÂ 634C
800
640
916
732.8
180×100×145
2050
JETÂ 634D
910
728
1034
834.2
180×100×145
2100
JETÂ 634E
1000
800
1145
916
180×100×145
2260
JETÂ 634F
1130
904
1274
1019.2
180×100×145
2490
JETÂ 634G
1250
1000
1386
1108.8
180×100×145
2820
JET Series Brushless Synchronous Alternator are made adopted Stamford alternators technology and according to the standards of GB755,IEC60034,NEMA etc. The alternators have standard features: voltage adjust, stability adjust, under frequency roll off, over exciting protection, low radio interference, etc. The stators are 2/3 pitch winding, the rotors are fixed sequential damper winding. The stator core is designed landler taking advantage of CAD, ensuring a very low waveform distortion. "H" class insulation system is provided the high build required for static windings and the high mechanical strength required for rotating components.
Alternator Features:
Â
1)Advanced automatic voltage regulator control for trouble-free operation under the most demanding condition
2)Easy paralleling with mains or other generators .Standard 2/3 pitch windings avoid excessive neutral currents.
3) Dynamically balanced rotor, with sealed-for-life ball bearings and single or two-bearing construction.
4)Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts.
5)Wide range of Flange adaptor and single bearing coupling disc.
Â
MECHANICAL FEATURES
Â
Voltage regulation
Â
Voltage regulation refers to the change of voltage from no-load to full-load with power factor ranging from 0.5 to 1 and 2.8%s fluctuation of the speed of engine. Voltage is adjusted via potentiometer of AVR, model: SX460, SX440
Â
Axis and Key
Â
All of alternator rotors should pass balance test, whose vibrations are lower than the minimum of BS6861 P.1,G 2.5 two bearing alternator has a half-key testing balance
Â
Terminal and terminal box
Â
The three-field alternator had 12 leads brought out to the terminals in the terminal box. The terminals are put on the non drive end . The box is equipped with removable panels.
Â
Â
ELECTRIC FEATURES
Insulation Class H
Â
All regulatory components are made up with special materials and are immersed in lacquer by peculiar tech. Vanish and colophony materials are develop to strengthen the processing and machinery intensity of windings and revolving parts for protecting the alternator work under corrosive environment.
Â
Winding and electric features
Â
2/3 pith winding design can effectively eliminate the third harmonic wave(3th.9th,15th) of the voltage ,which is the best design of UPS for nonlinear load .Connected with the network in parallel, the structure can restrain excessive currents in the midline. This and the 2/3 pitch help to check the wave distortion and output voltage.
Â
Phone interference and Radio interference
Â
THF (defined by 40thpart of BS4999) <2%.TIF<50
Brushless apparatus and quality AVR ensure little radio interference in transmission. RFI noise filter is also available.
Â
Accessories & Option
Â
Droop kit for sharing of reactive current during parallel operation
Remote voltage potentiometer
PT100 thermal protection embedded in stator windings
Anti condensation heaters
IP23 protection
Special treatment for damp-saline or corrosive Environment
PMG
Control panel with LCD digital meter
Â
Manufacturing Standard
Â
GB755, PART 3 of BS5000, VDE0530, UTE5100, NEMA MG1-22, CEMA, IEC34-1, CSA22.2 and AS1359.
Â
Warranty policy
Â
JET product has guarantee for one year or 1200 hours whichever reach first from ex-factory date. During the guarantee period, our will provide the free easy-damageable spare parts of alternator caused by our quality of production or raw material. After expiration, our provides cost spare parts maintenance of alternator.
Â
Detailed description
1.Brushless synchronous alternator with Stamford technology.
2.Output range:6.5kw - 1150kw single-phase and three-phase
3.High-performance Convenient installation and maintenance
4.Three phase 4 wire, optional 50Hz/60Hz, 1500/1800RPM
5.4-pole, brushless alternator with AVR, H class insulation, IP21
6. Be suitable for various brands engine, international standard SAE port, double bearing as optional
Specifications:
Â
MODEL
3-PHASE 50Hz /1500RPM 380V-440V
3-PHASE 60Hz /1800RPM 440V-480V
DIMENSION
WEIGHT
(KVA)
(KW)
(KVA)
(KW)
CM
KG
JETÂ 164A
8.1
6.5
10.2
8.2
64×54×72
95
JETÂ 164B
11
8.8
13.8
11
64×54×72
102
JETÂ 164C
13.5
10.8
16.9
13.5
64×54×72
110
JETÂ 164D
16
12.8
20
16
64×54×72
116
JETÂ 184E
22.5
18
28.8
23
84×59×75
133
JETÂ 184F
27.5
22
34.4
27.5
84×59×75
156
JETÂ 184G
31.3
25
37.5
30
84×59×75
172
JETÂ 184H
37.5
30
46.9
37.5
84×59×75
226
JETÂ 184J
40
32
50
40
84×59×75
236
JET 224C
42.5
34
52.5
42
96×66×102
275
JET 224D
50
40
62.5
50
96×66×102
295
JET 224E
60
48
70
56
96×66×102
315
JET 224F
72.5
58
87.5
70
96×66×102
345
JET 224G
85
68
97.5
78
96×66×102
385
JETÂ 274C
100
80
118
94
126×76×102
415
JETÂ 274D
114
91
138
110
126×76×102
435
JETÂ 274E
140
112
168
134
126×76×102
485
JETÂ 274F
160
128
190
152
126×76×102
530
JETÂ 274G
175
140
213
170
126×76×102
580
JETÂ 274H
200
160
245
196
126×76×102
630
JETÂ 274J
230
184
281
224.8
130×76×102
750
JETÂ 274K
250
200
299
239.2
130×76×102
760
JETÂ 444C
250
200
294
235
151×79×107
880
JETÂ 444D
295
236
350
280
151×79×107
950
JETÂ 444E
325
260
394
315
151×79×107
1065
JETÂ 444FS
380
304
456
365
151×79×107
1145
JETÂ 444F
400
320
480
384
151×79×107
1185
JETÂ 544C
450
360
550
440
165×95×116
1350
JETÂ 544D
500
400
594
475
165×95×116
1450
JETÂ 544E
600
480
713
570
165×95×116
1700
JETÂ 544FS
625
500
725
580
165×95×116
1753
JETÂ 544F
670
536
775
620
165×95×116
1820
JETÂ 634B
750
600
855
684
180×100×145
2020
JETÂ 634C
800
640
916
732.8
180×100×145
2050
JETÂ 634D
910
728
1034
834.2
180×100×145
2100
JETÂ 634E
1000
800
1145
916
180×100×145
2260
JETÂ 634F
1130
904
1274
1019.2
180×100×145
2490
JETÂ 634G
1250
1000
1386
1108.8
180×100×145
2820
JET Series Brushless Synchronous Alternator are made adopted Stamford alternators technology and according to the standards of GB755,IEC60034,NEMA etc. The alternators have standard features: voltage adjust, stability adjust, under frequency roll off, over exciting protection, low radio interference, etc. The stators are 2/3 pitch winding, the rotors are fixed sequential damper winding. The stator core is designed landler taking advantage of CAD, ensuring a very low waveform distortion. "H" class insulation system is provided the high build required for static windings and the high mechanical strength required for rotating components.
Alternator Features:
Â
1)Advanced automatic voltage regulator control for trouble-free operation under the most demanding condition
2)Easy paralleling with mains or other generators .Standard 2/3 pitch windings avoid excessive neutral currents.
3) Dynamically balanced rotor, with sealed-for-life ball bearings and single or two-bearing construction.
4)Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts.
5)Wide range of Flange adaptor and single bearing coupling disc.
Â
MECHANICAL FEATURES
Â
Voltage regulation
Â
Voltage regulation refers to the change of voltage from no-load to full-load with power factor ranging from 0.5 to 1 and 2.8%s fluctuation of the speed of engine. Voltage is adjusted via potentiometer of AVR, model: SX460, SX440
Â
Axis and Key
Â
All of alternator rotors should pass balance test, whose vibrations are lower than the minimum of BS6861 P.1,G 2.5 two bearing alternator has a half-key testing balance
Â
Terminal and terminal box
Â
The three-field alternator had 12 leads brought out to the terminals in the terminal box. The terminals are put on the non drive end . The box is equipped with removable panels.
Â
Â
ELECTRIC FEATURES
Insulation Class H
Â
All regulatory components are made up with special materials and are immersed in lacquer by peculiar tech. Vanish and colophony materials are develop to strengthen the processing and machinery intensity of windings and revolving parts for protecting the alternator work under corrosive environment.
Â
Winding and electric features
Â
2/3 pith winding design can effectively eliminate the third harmonic wave(3th.9th,15th) of the voltage ,which is the best design of UPS for nonlinear load .Connected with the network in parallel, the structure can restrain excessive currents in the midline. This and the 2/3 pitch help to check the wave distortion and output voltage.
Â
Phone interference and Radio interference
Â
THF (defined by 40thpart of BS4999) <2%.TIF<50
Brushless apparatus and quality AVR ensure little radio interference in transmission. RFI noise filter is also available.
Â
Accessories & Option
Â
Droop kit for sharing of reactive current during parallel operation
Remote voltage potentiometer
PT100 thermal protection embedded in stator windings
Anti condensation heaters
IP23 protection
Special treatment for damp-saline or corrosive Environment
PMG
Control panel with LCD digital meter
Â
Manufacturing Standard
Â
GB755, PART 3 of BS5000, VDE0530, UTE5100, NEMA MG1-22, CEMA, IEC34-1, CSA22.2 and AS1359.
Â
Warranty policy
Â
JET product has guarantee for one year or 1200 hours whichever reach first from ex-factory date. During the guarantee period, our will provide the free easy-damageable spare parts of alternator caused by our quality of production or raw material. After expiration, our provides cost spare parts maintenance of alternator.
Â
Three Phase Double Bearing 100kw 125kVA Brushless Alternator
Model NO.: JET274
Color: Red / Yellow / Blue / Black / Green / Gray
Power Range: From 2kw to 50kw
Trademark: JET POWER
Transport Package: Plywood
Specification: Rotor and Stator Made by 100% COPPER
Origin: China
HS Code: 8501610000
Model NO.: JET274
Color: Red / Yellow / Blue / Black / Green / Gray
Power Range: From 2kw to 50kw
Trademark: JET POWER
Transport Package: Plywood
Specification: Rotor and Stator Made by 100% COPPER
Origin: China
HS Code: 8501610000
Detailed description