Electromagnetic Slurry Flow Meter (A+E 81F) Highlights Features Item slurry flow meter Applicable pipe size DN 15-800 (1/2'' to 31-1/2'') Applicable media liquid with conductivity > 5 uS / cm Accuracy 0.5%FS, 1.0%FS Process connection flange, ANSI / GB / JIS, 1.0MPa, 1.6MPa, 4.0MPa, 16MPa optional Processing temperature -20 to 150°C, according to lining material Ambient condition -40 to 80°C, relative humidity <95% Power supply AC220V, 50Hz / DC24V / battery Display backlight LCD Operation 4 light touch buttons Signal output 4-20mA, loading resistance 750Ω, pulse, 0-3kHz, 5V, RS485 Consumption <8W Cable inlet/outlet M20*1.5 Protection transducer IP68, converter IP65 Tube material carbon steel, stainless steel optional Lining material PTFE, rubber, polyurethane, F46, Fs optional Electrode material stainless steel, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum optional Grounding made into a third electrode, same material with electrode Industries chemical, environmental, metallurgical, pharmaceutical, papermaking, water supply and drainage, etc. Main performances of the lining materials Lining material Main Performance Applications Teflon 1.The most steady material in plastics which is resistible to boiling hydrochloric acid, vitriol fortis as well as strong alkali and organic impregnates.     Strong corrosive mediums such as strong acid and alkali F46 1.Have the same abrasion resistance with PTFE. 1.The same as PTFE. Neoprene 1.Be of good elasticity, retractility and abrasion resistance. Water, sewage and slurry, mineral serosity of low abrasion. Polyurethane 1.Be of good abrasion resistibility. Applicable in mineral serosity, slurry and coal slurry of high abrasion. Main performances of the electrode materials Electrode material  Applications Stainless steel SS316 Applicable in water, sewage and corrosive mediums. Widely used in industries of petrol, chemistry, carbamide, etc. Hastelloy B(HB) Having strong resistance to hydrochloric acid of any consistence which is below boiling point. Also resistible against vitriol, phosphate, hydrofluoricacid,organic acid etc which are oxidable acid, alkali and non-oxidable salt. Hastelloy C(HC) Be resistant to oxidable acid such as nitric acid, mixed acid as well as oxidable salt such as Fe+++,Cu++and sea water Titanium Applicable in seawater, and kinds of chloride, hypochlorite salt, oxidable acid (including fuming nitric acid), organic acid, alkali etc. Not resistant to a pure reducing acid(such as sulphuric acid, hydrochloric acid)corrosion. But if acid contains antioxidant(such as Fe+++,Cu++) is greatly reduce corrosion. Tantalum Having strong resistance to corrosive mediums that is similar with glass. Almost applicable in all chemical mediums. Except for hydrofluoric acid, oleum and alkali. Platinum-iridium Almost be applicable in all chemical mediums except for aqua fortis, ammonium salt.
Automatic syringe assembly machine is a kind of medical machines to assemble parts of syringe to be one complete product. There are many types of our syringe assembly machines, 3-part syringe assembly machine for syringe with gasket, 2-part syringe assembly machine for syringe without gasket, insulin syringe assembly machine, safety syringe assembly machine etc.
Advantages of our syringe assembly machine:
1. Highly automatic
2. High production speed
3. Stable performance
4. Easy operation
Technical Parameter:
Name: 3-part syringe assembly machine
Dimension: 4200*3000*2100mm
Weight: 1500kg
Production Speed: 250pcs/min
FAQ:
1. Are you a manufacturer?
Yes, we are the professional manufacturer set up in 1992, located at a beautiful town of Zhejiang Province.
2. Can you provide the oversea service?
Yes, after the machines arrive at your factory, we will arrange engineers go to install the machine and train your operators.
3. Can we visit your factory?
Of course. We highly welcome clients come to visit our factory. It will be our great honor to meet you.
4. How can you guarantee the quality?
100% qualified products before the delivery. The clients can inspect the products at our factory.
1 year warranty ( failure caused by machine quality ) from the equipment arrive at the client`s factory. Lifetime maintenance and offer for the spare parts.
Syringe Assembly Machine Syringe Assembly Machine,Syringe Machine,Disposable Syringe Machine,Disposable Injection Syringe Machine Fuzhou Zhengri Technology Co., Ltd. , http://www.syringemachine.com
--aluminum alloy housing slurry flow meter, good enclosure.
--unique 6 layer circuit board design, immune to electromagnetic interference.
--fault detective supported like excitation circuit turn-off.
--plug & play terminal block
--damp-proof sealed sensor treatment
--reliable blank pipe inspection
--anti abrasive hard rubber lining material .
--electric conductivity of medium can be used for detection of product change.
--no additional pressure loss magnetic flow meter.
--no moveable parts and long working life.
--site digital LCD displays instantaneous flow, accumulative flow, flow rate.Â
--various output method, like 4-20mA, 0-5V, RS485 and pulse.
--compact, split and plug-in types optional.
--change the grounding as the third electrode.
2.Not be perfect in abrasion resistance.
2.Resistable for low abrasion.
3.Having strong resistance to load pressure.
2.Applicable in mediums of low abrasion.
2.Be resistant to low acid, alkali and salt but not for oxidation mediums.
2.Not be perfect in acid/alkali resistance.
3.Can't be used for water mixed with organic impregnants.
Warranty
All AEAD manufactured slurry flow meters are guaranteed in 12 month since delivery.Â
CompanyÂ
AEAD Technology moves to Chinese first free trade zone --Shanghai Pilot Free Trade Zone in Nov. 2014. That is a milestone for the company development to global market.Â
AEAD Technology is committed to provide the very best support possbile. Our customers have unique service needs, and we offer a variety of service options to support them. For any questions, you will either get the answer or have one of our professionals to contact you within 24 hours.
How to contact us?
If you are interested in slurry flow meter, please call our office at +86-(0)21-5869 6328.
Alternatively, you can send us an email or use the contact form which can be found on the contact page of our website.
Electromagnetic Slurry Flow Meter
Model NO.: A+E 81F
Measuring Media: Liquid
Measuring Principle: Electrical Principles
Measurement Object: Closed Pipeline
Certification: CE, ISO
Item: Slurry Flow Meter
Velocity Range: 0.2~8 M / S (0.66 to 26.26 Ft / S)
Electrode: 316L, Hc, Hb, Ti, Ta
Output: 4-20mA DC, Pulse, RS485
Pressure: Max.16 MPa
Media Temperature: 80 C
Ambient Temperature: Sensor 80 C, Converter 50 C
Power Supply: 220VAC or 24VDC
Grounding: Made as Third Electrode
Lining Material: Hard Rubber
Trademark: AEAD
Transport Package: Carboard Box, Wooden Case
Origin: Shanghai
HS Code: 90261000
Specifications