model: SK-600-NH3 Gas detection: Ammonia in the air examination range: 0-100ppm, 500ppm, 1000ppm, 5000ppm, 0-100% LEL Resolution: 0.1ppm, 0.1% LEL Display method: LCD Temperature and humidity: Optional accessories, temperature detection range: -40 to 120°C, humidity detection range: 0-100% RH Detection method: Diffusion, circulation, pump suction optional Installation method: Wall-mounted, ducted Detection accuracy: ≤±3% Linear error: ≤±1% Response time: ≤ 20 seconds (T90) Zero drift: ≤±1%(FS/year) Recovery Time: ≤ 20 seconds Repeatability: ≤±1% Signal output: 1 4-20mA signal: standard 16-bit precision 4-20mA output chip, transmission distance 1Km transfer method: 1 Cable transmission: 3-core, 4-core cable, long-distance transmission (1-2 kilometers) Receiving equipment: User computer, control alarm, PLC, DCS, etc. Alarm method: Live sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc. Alarm Settings: Standard configuration of two-level alarm, optional three-level alarm; can be set to alarm: conventional high and low alarm, interval control alarm Electrical interface: 3/4′′ NPT internal thread, 1/2′′ NPT internal thread, also supports 2 kinds of electrical connection Explosion-proof mark: ExdII CT6 (explosion-proof type) Shell material: Die Cast Aluminum + Sandblast Oxidation / Fluorocarbon Paint, Explosion Protection Protection level: IP66 Operating temperature: -30 to 60°C Working power: 24VDC (12 to 30VDC) Working humidity: ≤95%RH, no condensation size and weight: 183×143×107mm (L×W×H) 1.5Kg (net weight of the instrument) Work pressure: 0 to 100Kpa Standard accessories: Manual, certificate Warranty: One year These control valves play a crucial role in ensuring the efficient and effective operation of water treatment systems. Filter Control Valve,Automatic Softener Valve,Manual Control Valve,Softener Control Valve Hebei Chengda Water Technology Co.,Ltd. , https://www.arclionchengda.com
Ammonia gas detector Product Description:
Online ammonia NH3 gas detector, suitable for real-time accurate detection of NH3 gas concentration and leakage in various environments, using imported electrochemical sensors and microcontroller technology. Fast response, high measurement accuracy, stability and repeatability Benefits such as good. Explosion-proof wiring is suitable for all kinds of dangerous places, and is compatible with a variety of control alarms, PLC, DCS and other control systems, can simultaneously achieve on-site alarm warning, 4-20mA standard signal output, relay switch output; perfect Display various technical indicators and gas concentration values; also have a variety of extremely strong circuit protection functions, effectively prevent all kinds of human factors, instrument damage caused by uncontrollable factors;
Shenzhen East Japan Solar Technology NH3 gas alarm in different application environments or industries have different aliases, such as ammonia detector ammonia gas detector ammonia detector ammonia probe portable ammonia probe ammonia gas detection device )
Ammonia gas detector product features:
★ imported electrochemical sensors have good anti-jamming performance, and the service life is as long as 3 years;
★Using advanced microprocessor technology, fast response, high measurement accuracy, good stability and repeatability;
★ Live sound and light alarm function on the test site, real-time alarm when the gas concentration exceeds the limit, is the safety guarantee of dangerous on-site operations;
★ Large-screen LCD display with backlight, visual display gas concentration / type / unit / working status;
★ independent air chamber, sensor replacement is convenient, replacement does not require on-site calibration, the sensor key parameters automatically identify;
★ Full range temperature digital automatic tracking compensation to ensure measurement accuracy;
★ Semiconductor nanotechnology ultra-low power 32-bit micro-measurer;
★ All software automatic calibration, sensor up to six levels of target calibration function, to ensure the accuracy and linearity of the measurement, and has a data recovery function;
★ With overvoltage protection, lightning protection, short circuit protection, reverse connection protection, anti-static interference, anti-magnetic field interference and other functions;
And with automatic recovery function to prevent external causes, human factors, natural disasters and other equipment damage;
★ All Chinese/English operation menu, simple and practical, with temperature compensation function;
★ PPM, %VOL, mg/m3 concentration units can be switched freely;
★ Anti-high concentration gas impact automatic protection function;
(Targeted applications for different industries include: Ammonia alarms High-precision ammonia analyzer Ammonia detection module Ammonia sensor RS485 signal output Ammonia alarm 4-20mA signal output Ammonia alarm Fixed type Ammonia with LCD display Detector with display with sound and light alarm fixed ammonia detector and other product models)
2 RS485 signal: standard MODBUS RTU protocol, transmission distance 2Km
3 Voltage signal: 0-5V, 0-10V output, 4 pulse signal can be set by yourself: also called frequency signal, frequency range is adjustable (optional)
5 switch signal: standard 2 sets of relays, optional third set of relays, relay passive contacts, capacity 220VAC 3A/24VDC 3A
2 GPRS transmission: built-in GPRS module, real-time remote transmission of data, not limited by distance (optional)
Design Standard GB50493-2009 "Code for the Design and Detection of Combustible and Toxic Gases in Petrochemical Enterprises"
GB12358-2006 General Technical Requirements for Environmental Gas Detection and Alarming Devices in Workplaces
Implementation of the standard GB3836.1-2010 "Electrical equipment for explosive gas atmospheres Part 1: General requirements"
GB3836.2-2010 "Electrical Equipment for Explosive Gas Environments Part 2: Flameproof Type "d""
Shenzhen Dongri Solar Energy Technology has always been at the forefront of the industry. It is one of the earliest manufacturers engaged in the production of gas detectors in Shenzhen; a well-known brand of gas detectors in China; a national explosion proof certificate certification unit; a variety of products (gas sensors, gas sensor modules, Infrared gas sensors, gas alarms, portable gas detectors, etc.) Exquisite technology and perfect after-sales service Shenzhen Dongri Solar Energy NH3 gas alarm will be sent safely to Yunnan Province, Fujian Province, Taiwan Province, Hainan Province, Shanxi Province, Sichuan Province, Shaanxi Province, Guizhou Province, Anhui Province, Chongqing, Beijing, Shanghai, Tianjin, Guangxi, Inner Mongolia, Tibet, Xinjiang, Ningxia, etc. Each local application site needs oil and petrochemical, chemical plants, smelters, Steel plants, coal plants, thermal power plants, pharmaceutical scientific research, pharmaceutical production plants, tobacco companies, environmental monitoring, school research, building construction, fire alarms, sewage treatment, industrial gas process control, boiler rooms, garbage treatment plants, tunnel construction, oil pipelines , gas station, underground gas pipeline overhaul, indoor air quality inspection Hazardous Locations security, aerospace, equipment monitoring.
Shenzhen Dongri Solar Technology & Technology Ammonia NH3 Gas Alarm Keyword:
Ammonia Detector Ammonia Transmitter Ammonia Detector Ammonia Alarm Ammonia Probe Ammonia Probe Manufacturer Ammonia Probe Price Portable Ammonia Probe Ammonia Detection Ammonia Alarm Ammonia Analyzer Ammonia Detection Module Ammonia sensor RS485 signal output Ammonia alarm 4-20mA signal output Ammonia alarm Fixed type Ammonia detector with LCD display with sound and light alarm Fixed ammonia detector Ammonia leakage accident Emergency response method Objectives (1) In order to control and eliminate the hazards of liquid ammonia equipment leakage accidents in a timely manner, to minimize the casualties and property losses caused by the accident. This solution is applicable to the liquid ammonia refrigerating system and the cold burst liquid ammonia (ammonia) in the company. Accidents and Rescue of Leakage, Fire and Explosion Ammonia Detector Ammonia Transmitter Ammonia Detector Ammonia Alarm Ammonia Probe Ammonia Probe Manufacturer Ammonia Probe Price Portable Ammonia Probe Ammonia Detection Unit Ammonia Alarm Device II. Types of Leakage and Harmfulness Analysis 1. Analysis of Hazard Characteristics of Ammonia 1) Physical and Chemical Properties of Liquid Ammonia: Ammonia is a colorless, transparent and irritant Odor of gas. Easily soluble in water, the aqueous solution is alkaline. Relative density 0.60 (air = 1). When ammonia gas is pressurized to 0.7-0.8 MPa, it becomes liquid ammonia, and a large amount of heat is released. On the contrary, liquid ammonia absorbs a large amount of heat when it evaporates, so ammonia can be used as a refrigerant, and contact with liquid ammonia can cause severe frostbite. Its inexpensive features are widely used in the ice-making and refrigeration industries.
2) Hazard categories: Class 2, 3 toxic gases, 8 corrosives. The fire and explosion danger category is Category B. When ammonia and air are mixed to a certain percentage, the explosion can be caused by an open flame. The explosion limit is 15.5-25%.
3) Ammonia has a high volumetric expansion coefficient. When the volume of liquid ammonia is in the range of 0-60°C and the temperature of liquid ammonia is increased by 1°C, the pressure of the liquid increases by 1.32-1.80MPa, thus the liquid ammonia. Overfilling the container can easily cause an explosion.
4)
2. Hazard Analysis of Liquid Ammonia Leakage (1) Low concentration ammonia has irritating effect on mucous membranes. High concentrations of ammonia can cause tissue necrosis, chemical inflammation of the skin and upper respiratory mucosa, burns, pulmonary congestion, pulmonary edema and hemorrhage.
(2) Eye contact: Immediately lift the lid and rinse thoroughly with plenty of running water or saline solution for at least 15 minutes. Get medical attention.
(3) Inhalation: quickly leave the site to fresh air. Keep the airway open. If breathing is difficult, give oxygen. If breathing stops, give artificial respiration immediately. Get medical attention.
(4) Mild poisoning: Eyes, mouth pungency, runny nose, cough, hoarseness, difficulty swallowing, dizziness, headache, conjunctival hyperemia, edema, lips and mouth, eye congestion, chest tightness and sternal area pain, etc. .
(5) Severe poisoning: Inhalation of high concentrations of ammonia can cause laryngeal edema, throat phlegm, and suffocation. Exposed skin may have a degree II chemical burn, eyelid, lips, nose, pharynx and laryngeal edema, mucosal erosion, may have ulcers.
(6) Environmental hazards. It is harmful to the environment, can cause pollution to the atmosphere and cause frostbite to animals and plants. Discharge of water to be dissolved, sent to the professional department to deal with.
3. Equipment parts that are prone to accidents (1) Vapor phase inlet/outlet of liquid ammonia storage tank, liquid phase inlet/outlet, sewage outlet, discharge buckle, liquid gauge excuse, pressure gauge excuse, etc. Take over, valve, flange connection, etc. Failure or leakage. (2) Ammonia piping flanges, valves, and flanges fail or leak seals;
(3) leakage or burst of hose for ammonia tanker loading and unloading;
(4) Ammonia cylinder leaks or explodes.
Shenzhen Dongri Solar Energy Technology: high-precision ammonia analyzer ammonia detection module ammonia sensor RS485 signal output ammonia alarm 4-20mA signal output ammonia alarm fixed with liquid crystal display ammonia detector with display Sound and light alarm fixed ammonia detector
Filter valves are responsible for controlling the filtration process, which removes impurities and particulate matter from the water. They can be further classified based on their control methods, such as manual, semi-automatic, or fully automatic.
Softening valves, on the other hand, are designed to remove hardness-causing minerals like calcium and magnesium from the water. They can be categorized based on the number of tanks controlled by a single valve, such as single tank or multi-tank systems.
Additionally, softening valves can be classified based on the automatic regeneration method used. This includes time-based regeneration, meter-based regeneration, or demand-initiated regeneration.
The flow direction of the regeneration liquid is another factor that determines the type of softening valve. It can be either downflow, upflow, or counter-current flow.
The control method of softening valves refers to how the valve is operated and controlled. It can be manual, semi-automatic, or fully automatic, depending on the level of automation and control desired.
In industrial applications, softening valves are commonly used for treating boiler feed water. The removal of hardness-causing minerals helps prevent scale formation and improves the efficiency and lifespan of the boiler.
Ammonia NH3 Gas Concentration Detection Eight Hebei Cowshed Projects Completed in June
Ammonia NH3 Gas Concentration Detection The 8 ammonia cowshed projects in Hebei completed the testing of the ammonia concentration in the finished cowshed in June. The Shenzhen Dongri Solar Technology Model: SK-600-NH3 can be used. If you connect the PLC system, you can also use Shenzhen Dongri. Hanneng Technology's ammonia concentration detection module SK-NH3, the specific detailed engineering information can contact the technical personnel of Shenzhen Dongri Solar Energy Technology Co., Ltd. The following are the technical parameters and data of the ammonia gas detector.