Use of self-operated pressure regulating valve

Self-operated pressure control valve does not require other external energy sources such as power, gas source, the media alone to drive their own energy, energy saving and environmental protection, easy to use, set the pressure value after installation can be put into automatic operation, so in The control accuracy is not high, but also the lack of power, gas source of the occasion, has been more widely used. However, this valve also need to properly select the correct type and installation, use, to ensure that put into operation without any problems. Needless to say on the selection, such as the control valve is used to control the pressure before or after the valve pressure, the medium is room temperature or high temperature, whether corrosive, the maximum working pressure, etc., we must first figure out, we mainly talk about Talk about the installation and use of the issue. Because I recently encountered a case of self-service pressure regulator valve problems, very representative. Valve is used in the steam pipe, put into use just a month or two, the user on repair. A look to the scene, a lot of steam from the diaphragm vent valve discharge, noise, amazing momentum. The cause of the accident, obviously, the steam has not been condensed, directly into the membrane head, burned the diaphragm. Self-acting pressure regulating valve for steam pipe, the installation must be between the actuator and the pipe plus a condensate tank, the steam can not get into the actuator membrane, and, the control valve must be installed head-down, condensate tank to be higher than Film head, initial use, be sure to condense the tank and film head filled with water. Look at the installation site, on-site instrumentation staff, these are no problem, then what caused it? It is puzzling. Later, I carefully asked an operator, who inadvertently learned: This valve is installed, put into use, the condensate tank and the film between the brass fittings has been intermittently leaking. The original is the case, the water leakage led to the condensate tank slowly leak light, steam into the membrane head, burned the diaphragm. Thus, self-acting pressure regulating valve in the steam pipe when used, installation, maintenance must pay more attention to, in order to ensure the normal operation of the control valve, do not allow joints leaks, condensation can not be allowed to water, regular inspections, Timely water. In fact, not only self-pressure regulator, is the other self-regulating valve, also need to pay attention to the use of maintenance and care Caixing. In addition, if the steam pressure is higher, the best choice of piston actuators, rather than take the film actuator, because the diaphragm can withstand the pressure of not more than 0.4Mpa, though this can be used, but must greatly reduce the service life.

Christmas Gifts

Imitation bird Feather Bird Ornament color bird garden animal sparrow swallow pigeon hot sale home decoration ornament.Simulation bird feather feather bird binding bird model Taoism small animal teaching aids, pastoral style decoration, fake bird.Wedding bird lovers bird love bird lover gift simulation bird Wedding Dress Hat bird feather bird home decoration.4521

Christmas Gifts,Craft Legacy Cast,Christmas Gifts Baskets,Personalized Christmas Ornaments

Xintong Craft Gift Co.,LTD , https://www.jlxtcraft.com