Magnetic pump use and troubleshooting

Use caution

1. Because the cooling and lubrication of the magnetic pump bearing is based on the medium being conveyed, it is forbidden to run at idle, and at the same time, it can avoid the no-load operation caused by the start-up after a power failure.
2. If there are solid particles in the medium to be transported, the filter inlet should be added to the pump inlet: If it contains ferromagnetic particles, a magnetic filter must be added.
3. The ambient temperature of the pump during use should be less than 40°C and the temperature rise of the motor must not exceed 75°C.
4. The medium to be conveyed and its temperature should be within the allowable range of the pump. The working temperature of the engineering plastic pump is less than 60°C, the temperature of the metal pump is less than 100°C, the auxiliary suction pressure is not more than 0.2MPa, the working pressure is 1.6MPa, the density is less than 1600kg/m3, and the particle size is not more than 30X10-6. M2/S liquid without hard particles and fibers.
5. For the medium that is easy to precipitate and crystallize when the transport liquid is used, it should be cleaned and drained in the pump after use.
6. After the magnetic pump is operated for 500 hours, the wear and idle condition of the bearing and the face ring should be checked. If the clearance between the bearing and the shaft sleeve is greater than 0.5~1mm, the impeller should be replaced by the axial direction when it is 1.5~2mm. Moving ring.

Faults and Troubleshooting

Failure form

cause

Method of exclusion

No water pump

Pump reverse

Leakage of leaking water pipes

Pump cavity too little water

The voltage is too high and the coupling slips when starting

Suction lift is too high

Change the motor wiring

Society leaks

Increase water storage

Adjust the voltage

Reduce pump installation

Insufficient traffic

Suction tube diameter is too small

Impeller blocking

High lift

Low speed

Exchange the inlet pipe

Cleaning the impeller

Large outlet valve

Summer recovery rated speed

Head is too low

Excessive traffic

Low speed

Small outlet valve

Restore rated speed

Too loud

Serious shaft wear

Bush wear

Drive magnetic steel cup and isolation sleeve contact

Replace the pump shaft

Replace sleeve

Remove the pump head and reassemble

Leakage

Type 0 seal defect

Replacement type 0 seal