1. The setting of the timber yard, the waste rock mountain and the furnace ash yard complies with the provisions of Article 216 of the Regulations. 2. Strengthen the management of the fire prevention system, build the entire upper and lower fire pool and fire pipeline system to ensure the fire system is reliable, the water source is sufficient, and the water supply is normal. Otherwise, the responsible unit will be fined 100 yuan. 3. The fire equipment library set up and down, the fire protection equipment in the library is complete in variety, the quantity is in compliance with the regulations, the fire prevention and extinguishing facilities in the wells and the wells in the well, the wells are well equipped, the performance is good, the installation location, location and quantity meet the quality standards. Claim. 4. Special fire prevention measures must be prepared in the Mine Disaster Prevention Measures and Treatment Plan. Excavation work procedures must be carried out with special measures for fire prevention and strictly enforced. 5. All coal roadway roadway must be cleaned of floating coal, the air duct and cable should be suspended side by side, and the fire protection pipeline facilities are complete. 6. It is forbidden to accumulate combustible materials near the head of the belt conveyor. The head is 5 meters in front and rear. It is supported by incombustible brackets and has a certain amount of fire-fighting equipment. The driver should always clean the circumference of the roadway and the electrical equipment within 5 meters before and after the nose. coal. 7. Cave room and allowed downhole storage of gasoline, kerosene and transformer oil, lubricating oil for downhole use, cotton, cloth and paper, must be stored in tightly closed iron tub (boxes), used cotton, cloth and paper It must also be placed in a tight iron drum (box), and it will be sent to the ground by a special person on a regular basis. It is not allowed to throw it away. It is strictly forbidden to spill the leftover oil in the well and the chamber. 8. In the design of mining areas, there must be comprehensive and special measures to prevent spontaneous combustion and ignition of coal seams. 9. Strict wellhead body check system. It is strictly forbidden for anyone to carry fireworks, fire and flammable products to the well. Fireworks are prohibited within 20 meters near the wellhead. In case of violation of the regulations, the person responsible shall be fined 50 yuan. 10. Strengthen the management of underground electromechanical equipment. The underground power supply must be “three noesâ€, “four havesâ€, “two Qiâ€, “three full†and “three sticks†to eliminate electric fire sources. 11. Shooting and shooting carefully implement the "one shot three inspections", "three-person chain release system" and other specific regulations on the management of firearms, to prevent the fire source. 12. Conduct fire zone management in strict accordance with the requirements of the Regulations. 13. It is strictly forbidden to use bulbs and electric stoves for heating in underground, and electric welding, gas welding and torch welding are not allowed in underground and wellhead rooms. If it is necessary to carry out welding work in the main diverticulum, main inlet shaft and wellhead room, the construction unit will All safety measures must be formulated. After approval by the chief engineer, the director shall report to the company for approval and report to the company for filing, and designate a special person to inspect and supervise the site; the supervisor and the relevant units of the company shall send special personnel to supervise the site. 14. All units should strengthen the management of fire prevention facilities in this work area and check once a week to keep them in good condition. Page 2 / (2 pages in total) 15. Each quarter, the general manager organizes construction units, mine rescue teams, ventilation, electromechanical, security inspection, dispatching, public security firefighting and other relevant departments to the upper and lower fire protection pipeline systems, fire doors, The fire protection materials library and fire-fighting equipment and other fire-fighting facilities were inspected once and the problems were solved in time. 16. The ambulance team conducts a fire prediction and forecast inspection every ten days. The observation site and contents meet the standard requirements, and the results are reported to the ventilation area. 17. Strengthen the education on fire prevention and fire prevention for employees, so that employees can understand and master fire prevention, direct fire extinguishing and use various fire prevention facilities and equipment, improve the technical quality of fire prevention and disaster relief, and hold a class every six months. 18. Strictly implement the "Code for Mine Fire Prevention" and various regulations, and strictly follow the fire safety measures to conduct construction work, otherwise seriously investigate and deal with the criminal responsibility of the person causing the disaster. 19. If one of the following conditions is involved in fire prevention management, it should be rectified immediately. (1) Failure to provide fire-fighting equipment or fire-fighting equipment expired as required; (2) The types and quantities of fire protection materials or fire-fighting materials stored in the upper and lower parts of the well are not in accordance with the regulations; (3) storing flammable materials (gasoline, paint) in the underground working place or spilling the remaining paint on the roadway; (4) It occurred with small coal mines or old lanes, and was not permanently closed in time. 21. The mining area, working surface and abandoned roadway at the end of mining recovery shall be permanently sealed at the specified time. 22. Permanent derricks and wellhead rooms must be constructed of non-combustible materials. At least two fire extinguishers must be provided in the wellhead room for a long time, which is managed by the duty scheduler. 23. The production mine wood yard should be located on the downwind side of the main wind entering the wind shaft or away from the inlet well. 24. The production wellhead shall be provided with a fire fighting pool on the ground, and its water storage capacity shall not be less than 200 m3. 25. The upper level water tank can be used as a fire pool in the underground. There must be at least 200 m3 of water in the pool. 26. Within 20 meters of the wellhead room and the main ventilation machine room, there shall be no fireworks or furnaces. 27. The press-in duct of the hurricane furnace must be constructed of non-combustible materials. 28. No electric welding or gas welding work shall be carried out in the wellhead room. If it is really necessary to use, the mine technical person in charge shall prepare safety measures and report to the chief engineer for approval. 29. Inoue should have a fire protection material library in the non-wellhead room. The fire materials library should have a rail to the wellhead. 30. The variety and quantity of materials and tools stored in the fire protection materials warehouse shall comply with relevant regulations. It should be inspected and replaced regularly; materials and tools must not be used for other purposes. 31. The mining face must be retracted. When the coal mining face is taken to the stop line, measures must be taken to make the roof fall tight. 32. After the coal mining face is finished, it must be permanently closed within 45 days. 33. The alleys transported by underground wire-type electric vehicles must be supported by non-combustible materials. 34. The floating coal in the underground roadway must be cleaned regularly every day. japanese car lexus exhaust manifold adapter kit,japanese car lexus exhaust manifold adapter,japanese car lexus exhaust manifold assembly Ningbo Lingmai Machinery Manufacturing Co., Ltd. , https://www.lingmaimfg.com
Fire prevention measures
All mine ground buildings, coal heap, fire prevention measures and institutional waste dump, timber yard, etc., and must comply with the provisions of the National Fire Protection and meet the requirements of the local fire department.