Electronic fence host installation and requirements

Installation and requirements of the electronic fence host:

1, the host placed a special cabinet protection;

2. The high-voltage lead-out line must be installed according to the standard configuration line provided by the original manufacturer. It must not be purchased separately. In case you need to purchase it yourself, you must obtain the insulation safety requirements of the original manufacturer's identification lead-out line. Otherwise, it may easily lead to accidental electric shock.

3. The grounding electrode must be installed in a relatively humid place to facilitate grounding protection. The distance between the three grounding electrodes should be about 3 meters, and the grounding should be extremely deep underground. The grounding pole must be located away from the telephone and telecommunication lines. It must be away from people and livelihoods. It must not be installed next to the water pipe. It must not be installed near feeding animals. It is better to stay away from such facilities for more than 15 meters. Where conditions are, the distance must not be less than 10m;

4. The jumper between the fences can be made of the same material as the fence line, but the two rows of fences need to be solid.


Installation and requirements for the front of the electronic fence:

1, the installation of the triangular bracket: the height of the bottom of the triangle bracket from the ground shall not be less than 4 meters, each bracket is fixed to the wall with three Φ12mm expansion bolts. The distance between the two brackets is 4-6 meters, and the upper plane of all brackets should be kept in the same plane.

2. Installation of high-pressure porcelain bottles: 4 P10-type porcelain bottles are mounted on each support. The bottle body is required to be horizontal and vertical. The bottle head is upward and the groove on the bottle head is required to be parallel to the wall surface.

3, put aluminum wire and wire fixation:

(1) First select the position of the subdivision point. From this point onwards, five aluminum strands of the same length shall be released at the position of the subdivision point.

(2) Each aluminum wire is fixed first, and then each wire is placed on the corresponding side of each bracket porcelain in this segment, as shown in the figure: Each aluminum stranded wire is placed in the corresponding position, in the tenth triangle. At the position of the bracket, each thread is tensioned with a tightener, and then the aluminum wire in this section is placed in the notch at the top of the corresponding bottle, and it is tied tightly with a tie.

(3) Nylon method: Cables are cut from aluminum strands and have a length of 1.7 to 2.3 meters. The intercepted aluminum strands can be divided into 5 to 6 each, and then each aluminum strand is discarded into small discs with a diameter of 5 to 8 cm. First of all, take the center of the cable tie as the standard, turn around the aluminum strand at the end of the bottle head for 1~3 turns, then take the one end of the tie wire as the standard, and turn it counterclockwise in the middle of the size of the porcelain bottle. After one and a half laps, the remaining cable is wound around the aluminum strand 5 times. Finally, tie the other end of the cable tie in the opposite direction, the same way as above.

4. Installation and construction method of subsections: First select the subdivision point in the appropriate place, that is, between the two brackets, and above the high-pressure box, connect the two network cables in the same position with the partition porcelain (insulator). it is good. The two network cables shall be respectively penetrated into corresponding round holes of the partitioned porcelain bottle. After the cable is tightened, the direction of force of the insulator should be pressed toward the center. If two aluminum wires only penetrate into the round holes near the end respectively, then the center of the insulator will receive the pulling force to both sides in the direction of force, and the porcelain bottle can be easily broken from the middle.


Fluted Candle

white Color paraffin wax Fluted candle also called velas, bougies, house hold candles, the candles surface with lines. Very beatiful .usually packed by color polybag. as client design, we also can design for client.

and 6pcs in polybag ,and 25bag/.ctn the weight 30-75g per piece to africa countries.

different market need different candles size ,we can supply best price as popular size

the shipment in the 30days after get the depsoit .